Brookfield LFRA Texture Analyzer Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Brookfield LFRA Texture Analyzer. Brookfield LFRA Texture Analyzer User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Brookfield Engineering Labs., Inc. Page 1 Manual No. M/05-370-A1205
BROOKFIELD LFRA
TEXTURE ANALYZER
Operating Instructions
Manual No. M/05-370-A1205
BROOKFIELD ENGINEERING LABORATORIES, INC.
11 Commerce Boulevard, Middleboro, MA 02346-1031 USA
SPECIALISTS IN THE
MEASUREMENT AND
CONTROL OF VISCOSITY
TEL 508-946-6200
F
AX 508-946-6262
or 800-628-8139 (USA only)
I
NTERNET
www.brookfieldengineering.com
Vista de página 0
1 2 3 4 5 6 ... 29 30

Resumo do Conteúdo

Página 1 - Manual No. M/05-370-A1205

Brookfield Engineering Labs., Inc. Page 1 Manual No. M/05-370-A1205BROOKFIELD LFRATEXTURE ANALYZEROperating InstructionsManual No. M/05-370-A1205BR

Página 2 - TABLE OF CONTENTS

Brookfield Engineering Labs., Inc. Page 10 Manual No. M/05-370-A1205III.3 Base TableThe Base Table is designed to provide quick adjustment of the

Página 3 - I. INTRODUCTION

Brookfield Engineering Labs., Inc. Page 11 Manual No. M/05-370-A1205III.4 ProbesThere are a range of probes available for use with the LFRA Textur

Página 4

Brookfield Engineering Labs., Inc. Page 12 Manual No. M/05-370-A1205Once the test mode is selected the test parameters must be set.•Normal requires

Página 5

Brookfield Engineering Labs., Inc. Page 13 Manual No. M/05-370-A1205Data entry is accomplished by setting each digit individually. For example: to

Página 6

Brookfield Engineering Labs., Inc. Page 14 Manual No. M/05-370-A1205Depressing the Select / Scroll knob at any time during the test will display th

Página 7 - EMERGENCY STOP

Brookfield Engineering Labs., Inc. Page 15 Manual No. M/05-370-A1205Start the calibration verification process by using the Select / Scroll knob to

Página 8 - II. QUICK START

Brookfield Engineering Labs., Inc. Page 16 Manual No. M/05-370-A1205Example of Calibration Verification1000 gram LFRA Texture Analyzer, accuracy ac

Página 9 - III. OPERATION

Brookfield Engineering Labs., Inc. Page 17 Manual No. M/05-370-A1205IV. TEST METHOD DEVELOPMENTThe measurement results provided by the LFRA Texture

Página 10 - Locking Knob

Brookfield Engineering Labs., Inc. Page 18 Manual No. M/05-370-A1205Within a probe category, variations of geometry can be significant. It may req

Página 11

Brookfield Engineering Labs., Inc. Page 19 Manual No. M/05-370-A1205V. APPLICATIONSThis applications section should be used as a guide to the devel

Página 12

Brookfield Engineering Labs., Inc. Page 2 Manual No. M/05-370-A1205TABLE OF CONTENTSI. INTRODUCTION...

Página 13

Brookfield Engineering Labs., Inc. Page 20 Manual No. M/05-370-A1205was left between the sample surface and the base of the probe. This wasleft to

Página 14 - Hanger Mount

Brookfield Engineering Labs., Inc. Page 21 Manual No. M/05-370-A1205PARAMETER All parameters were automatically calculated within the Analyze a tes

Página 15

Brookfield Engineering Labs., Inc. Page 22 Manual No. M/05-370-A1205Sample conditions which will effect results generated:1. Fat content2. Protein

Página 16 - 500 495g 745g -744.0g pass

Brookfield Engineering Labs., Inc. Page 23 Manual No. M/05-370-A1205PROBE REF: 2mm stainless steel cylinder probe (REF: TA39)METHOD: Biscuits appro

Página 17 - IV. TEST METHOD DEVELOPMENT

Brookfield Engineering Labs., Inc. Page 24 Manual No. M/05-370-A1205PARAMETERS: HARDNESS Force necessary to attain a given deformationCONSISTENCY I

Página 18

Brookfield Engineering Labs., Inc. Page 25 Manual No. M/05-370-A1205LFRA SETTINGS: MODE: Measure force in compressionPLOT: FinalSPEED: 0.1mm/s-1DIS

Página 19 - V. APPLICATIONS

Brookfield Engineering Labs., Inc. Page 26 Manual No. M/05-370-A1205RESULTS: PARAMETER UNIT 2mm 4mm 6mmHARDNESS (g) 334 722 1159CONSISTENCY (gs) 31

Página 20 - READING:

Brookfield Engineering Labs., Inc. Page 27 Manual No. M/05-370-A1205Appendix A - Probes and FixturesProbesStandard Probe kit comes complete with th

Página 21

Brookfield Engineering Labs., Inc. Page 28 Manual No. M/05-370-A1205Conical ProbesTA2/100 60°, 30 mm D, Clear Perspex (low mass)TA2/1000* 60°, 30 m

Página 22

Brookfield Engineering Labs., Inc. Page 29 Manual No. M/05-370-A1205Appendix B - TroubleshootingIf no power to the instrument:Check:• User replacea

Página 23 - Distance

Brookfield Engineering Labs., Inc. Page 3 Manual No. M/05-370-A1205I. INTRODUCTIONThe Brookfield LFRA Texture Analyzer measures the resistance of a

Página 24

Brookfield Engineering Labs., Inc. Page 30 Manual No. M/05-370-A1205Appendix C - Warranty and Repair ServiceWarrantyBrookfield Texture Analyzers ar

Página 25 - each penetration depth

Brookfield Engineering Labs., Inc. Page 4 Manual No. M/05-370-A1205I.2 UtilitiesInput Voltage: 115 VAC or 230 VACInput Frequency: 50/60 HzPower Con

Página 26

Brookfield Engineering Labs., Inc. Page 5 Manual No. M/05-370-A1205Position: Range: 0-75 mmResolution: 0.1mmAccuracy: 0.1mmOutput: Computer: RS232

Página 27

Brookfield Engineering Labs., Inc. Page 6 Manual No. M/05-370-A1205I.6 Safety Symbols and PrecautionsSafety SymbolsThe following explains safety sy

Página 28

Brookfield Engineering Labs., Inc. Page 7 Manual No. M/05-370-A1205I.7 Key FunctionsThe LFRA Texture Analyzer is operated through two keys and a kn

Página 29 - Appendix B - Troubleshooting

Brookfield Engineering Labs., Inc. Page 8 Manual No. M/05-370-A1205II. QUICK START1. Unpack the instrument according to Section I.5.2. Attach the s

Página 30 - Warranty

Brookfield Engineering Labs., Inc. Page 9 Manual No. M/05-370-A1205III. OPERATIONIII.1 PrincipleThe Brookfield LFRA Texture Analyzer drives a prob

Comentários a estes Manuais