Brookfield LFRA Texture Analyzer Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Brookfield LFRA Texture Analyzer. Brookfield LFRA Texture Analyzer User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Brookeld Engineering Labs., Inc. Page 1 Manual No. M/05-370-B0507
SPECIALISTS IN THE
MEASUREMENT AND
CONTROL OF VISCOSITY
TEL 508-946-6200
FAX 508-946-6262
or 800-628-8139 (USA excluding MA)
I
NTERNET
http://www.brookfieldengineering.com
BROOKFIELD ENGINEERING LABORATORIES, INC.
11 Commerce Boulevard, Middleboro, MA 02346 USA
with offices in
:
BostonChicagoLondonStuttgartGuangzhou
BROOKFIELD LFRA
TEXTURE ANALYZER
Operating Instructions
Manual No. M/05-370-B0507
Vista de página 0
1 2 3 4 5 6 ... 45 46

Resumo do Conteúdo

Página 1 - Manual No. M/05-370-B0507

Brookeld Engineering Labs., Inc. Page 1 Manual No. M/05-370-B0507 SPECIALISTS IN THEMEASUREMENT ANDCONTROL OF VISCOSITYTEL 508-946-6200

Página 2 - TABLE OF CONTENTS

Brookeld Engineering Labs., Inc. Page 10 Manual No. M/05-370-B0507III.3 Base TableTheBaseTableisdesignedtoprovidequickadjustmentofth

Página 3 - I. INTRODUCTION

Brookeld Engineering Labs., Inc. Page 11 Manual No. M/05-370-B0507III.4 ProbesTherearearangeofprobesavailableforusewiththeLFRAText

Página 4

Brookeld Engineering Labs., Inc. Page 12 Manual No. M/05-370-B0507Once the test mode is selected the test parameters must be set. •Normalrequ

Página 5

Brookeld Engineering Labs., Inc. Page 13 Manual No. M/05-370-B0507Dataentryisaccomplishedbysettingeachdigitindividually.Forexample:

Página 6

Brookeld Engineering Labs., Inc. Page 14 Manual No. M/05-370-B0507A test may be repeated by simply pressing the Start button while viewing the

Página 7 - EMERGENCY STOP

Brookeld Engineering Labs., Inc. Page 15 Manual No. M/05-370-B0507Note: TheStartbuttonmaybeusedtozerotheLFRAatanytimeduringtheS

Página 8 - II. QUICK START

Brookeld Engineering Labs., Inc. Page 16 Manual No. M/05-370-B0507Example of Calibration Verication1000gramLFRATextureAnalyzer,accuracya

Página 9 - III. OPERATION

Brookeld Engineering Labs., Inc. Page 17 Manual No. M/05-370-B0507IV. TEST METHOD DEVELOPMENTThemeasurementresultsprovidedbytheLFRAText

Página 10 - Locking Knob

Brookeld Engineering Labs., Inc. Page 18 Manual No. M/05-370-B0507Withinaprobecategory,variationsofgeometrycanbesignicant.Itmayre

Página 11 - TEST: NORMAL

Brookeld Engineering Labs., Inc. Page 19 Manual No. M/05-370-B0507V. APPLICATIONSThisapplicationssectionshouldbeusedasaguidetothede

Página 12

Brookeld Engineering Labs., Inc. Page 2 Manual No. M/05-370-B0507TABLE OF CONTENTSI. INTRODUCTION ...

Página 13

Brookeld Engineering Labs., Inc. Page 20 Manual No. M/05-370-B0507  NOTE:Samplesweretestedwithoriginalcontainersassupplied.Useof

Página 14 - Hanger Mount

Brookeld Engineering Labs., Inc. Page 21 Manual No. M/05-370-B0507 PARAMETERS: HARDNESS Force necessary to attain a given deformationCONSI

Página 15

Brookeld Engineering Labs., Inc. Page 22 Manual No. M/05-370-B0507  Sampleconditionswhichwilleffectresultsgenerated: 1. Fat content

Página 16

Brookeld Engineering Labs., Inc. Page 23 Manual No. M/05-370-B0507 METHOD: Biscuits approximately 6 mm thick were located beneath the probe a

Página 17 - IV. TEST METHOD DEVELOPMENT

Brookeld Engineering Labs., Inc. Page 24 Manual No. M/05-370-B0507 PARAMETERS: HARDNESS Force necessary to attain a given deformationCONSIST

Página 18

Brookeld Engineering Labs., Inc. Page 25 Manual No. M/05-370-B0507 LFRA SETTINGS: MODE: Measureforceincompression  PLOT: Final  SPEE

Página 19 - V. APPLICATIONS

Brookeld Engineering Labs., Inc. Page 26 Manual No. M/05-370-B0507 RESULTS: PARAMETER UNIT 2mm 4mm 6mm HARDNESS (g) 334 722 115

Página 20 - READING:

Brookeld Engineering Labs., Inc. Page 27 Manual No. M/05-370-B0507Appendix A - Probes and FixturesProbesStandard Probe kit comes complete with

Página 21 - FACTORS: 1. Samplesize

Brookeld Engineering Labs., Inc. Page 28 Manual No. M/05-370-B0507Conical ProbesTA2/100 60°, 30 mm D, Clear Perspex (low mass)TA2/1000* 60°,

Página 22

Brookeld Engineering Labs., Inc. Page 29 Manual No. M/05-370-B0507Appendix B - TroubleshootingIf no power to the instrument:Check:• Userrepla

Página 23 - READING:

Brookeld Engineering Labs., Inc. Page 3 Manual No. M/05-370-B0507I. INTRODUCTIONTheBrookeldLFRATextureAnalyzermeasurestheresistanceof

Página 24

Brookeld Engineering Labs., Inc. Page 30 Manual No. M/05-370-B0507Appendix C - Use with TexturePro Lite SoftwareThe following screens show the

Página 25 - each penetration depth

Brookeld Engineering Labs., Inc. Page 31 Manual No. M/05-370-B0507TEXTUREPRO LITE README FILETHIS FILE APPEARS DURING INSTALLATION AND MAY BEVI

Página 26

Brookeld Engineering Labs., Inc. Page 32 Manual No. M/05-370-B0507SETTING VISUAL BASIC TRUSTEDSOURCES FOR MICROSOFT OFFICE THE EXAMPLE SHOWN IS

Página 27

Brookeld Engineering Labs., Inc. Page 33 Manual No. M/05-370-B0507SETTING UP A TESTDefine Test ParametersEnter testparametersENTER TEST TYPEENT

Página 28

Brookeld Engineering Labs., Inc. Page 34 Manual No. M/05-370-B0507SETTING UP A TESTDefine Test ParametersEnter testparametersENTER TEST TYPEENT

Página 29 - Appendix B - Troubleshooting

Brookeld Engineering Labs., Inc. Page 35 Manual No. M/05-370-B0507SETTING UP A TESTDefine Sample ParametersEnter sample informationas appropria

Página 30

Brookeld Engineering Labs., Inc. Page 36 Manual No. M/05-370-B0507SHORTCUT MENU BUTTONSDATA ANALYSIS AND OPERATIONTEST PROPERTIESDEFINE NEW TES

Página 31 - TEXTUREPRO LITE README FILE

Brookeld Engineering Labs., Inc. Page 37 Manual No. M/05-370-B0507SHORTCUT MENU BUTTONSDATA ANALYSIS AND OPERATIONCURRENT DATAADJUST PROBE POSI

Página 32 - AND ANALYZE DATA

Brookeld Engineering Labs., Inc. Page 38 Manual No. M/05-370-B0507SHORTCUT MENU BUTTONSDATA ANALYSIS AND OPERATIONCURRENT DATASTART TESTEXECUTE

Página 33

Brookeld Engineering Labs., Inc. Page 39 Manual No. M/05-370-B0507SHORTCUT MENU BUTTONSDATA ANALYSIS AND OPERATIONCURRENT DATAOVERLAY FILESLOAD

Página 34

Brookeld Engineering Labs., Inc. Page 4 Manual No. M/05-370-B0507I.2 UtilitiesInputVoltage: 115VACor230VACInputFrequency: 50/60HzPowe

Página 35

Brookeld Engineering Labs., Inc. Page 40 Manual No. M/05-370-B0507SHORTCUT MENU BUTTONSDATA ANALYSIS AND OPERATIONCURRENT DATAOPEN STORED DATA

Página 36 - DATA ANALYSIS AND OPERATION

Brookeld Engineering Labs., Inc. Page 41 Manual No. M/05-370-B0507SUMMARY OF SHORTCUT MENU BUTTONSTEST PROPERTIES: DEFINE A NEW TEST,OPEN A SA

Página 37 - CURRENT DATA

Brookeld Engineering Labs., Inc. Page 42 Manual No. M/05-370-B0507TEXTURE RESULTSSelecting Results for ReportsCHECK ALL DESIREDRESULTSGENERAL

Página 38

Brookeld Engineering Labs., Inc. Page 43 Manual No. M/05-370-B0507VIEWING TEST RESULT STATISTICS FROM MULTIPLE DATA FILESCURRENT DATASTATISTICS

Página 39

Brookeld Engineering Labs., Inc. Page 44 Manual No. M/05-370-B0507TO COMPARE RESULTS OF MORE THAN 10 DATAFILES, HIGHLIGHT THE ENTIRE STATISTICS

Página 40

Brookeld Engineering Labs., Inc. Page 45 Manual No. M/05-370-B0507SEE THE TEXTUREPRO HELP FILE FOR MORE DETAILS ON ALLASPECTS OF TEXTURE TESTIN

Página 41

Brookeld Engineering Labs., Inc. Page 46 Manual No. M/05-370-B0507Appendix D - Warranty and Repair ServiceBrookeldTextureAnalyzersareguara

Página 42 - PREFORMATTED TEST REPORT

Brookeld Engineering Labs., Inc. Page 5 Manual No. M/05-370-B0507Position: Range:0-75mm Resolution:0.1mm Accuracy:0.1mm Output: Comp

Página 43 - OVERLAYED DATA

Brookeld Engineering Labs., Inc. Page 6 Manual No. M/05-370-B0507 8) Allow the instrument to warm up for 10 minutes. Check calibration accor

Página 44

Brookeld Engineering Labs., Inc. Page 7 Manual No. M/05-370-B0507I.7 Key Functions TheLFRATextureAnalyzerisoperatedthroughtwokeysand

Página 45

Brookeld Engineering Labs., Inc. Page 8 Manual No. M/05-370-B0507II. QUICK START 1. Unpack the instrument according to Section I.5. 2. Att

Página 46

Brookeld Engineering Labs., Inc. Page 9 Manual No. M/05-370-B0507III. OPERATIONIII.1 PrincipleTheBrookeldLFRATextureAnalyzerdrivesapr

Comentários a estes Manuais

Sem comentários