BrookeldEngineeringLabs.,Inc. Page25 ManualNo.M08-218-B0212
Input of Values:
Val.[1/s]: 0290.00
Nr. of MP: 010
Time[s]: 0100
Note: If you press and hold one of the
or
keys while entering numbers, the digit will rst
increment or decrement by +/- 1. However, after a short period of time, the process will
continue automatically. This corresponds to the RepeatFunction of computer keyboards.
In this example, the
key was pressed and held until the “9” was displayed. Therepeat
functionisonlyactiveduringnumericalandalphanumericinput.
When the desired number is displayed, accept it by pressing the
OK
key: the cursor now moves
to the rst digit of the next eld to be entered.
Alphanumericinputs
Some elds allow for both numbers and letters. These are entered the same way as previously
discussed for numeric elds. The available entries are: 0 through 9, A through Z, and the blank
symbol “ ”. If you wish to change the letter “B” to the number “7”, press and hold the
or
keys until the “7” appears at the display.
Alphanumeric input is available when assigning a name to a user dened program, or an ID to a
user dened test measurement.
VI.5 MenuEntries(MAINMenu)
Menu entries (see Section VI.2: Menu System of R/S-CPS+ Rheometer) either lead to submenus
(e.g. Utilities or Conguration), or they start one of the rheometers functions directly.
All gray elds in the tree chart in this section that have no further right branches start functions.
Those with right branches are submenus.
Recall the keyboard layout from Section VI.1. By pressing the
and
keys, the cursor
(black rectangle) moves up and down. The
OK
key starts a function. If a submenu is assigned
to the entry it will open, otherwise the function of the rheometer is started. The functions of the
R/S-CPS+ Rheometer are described in detail in this section.
VI.5.1 MAINMenu Bath/Circulator(onlyforP1andP2models)
This optionally available menu item permits an adjustment of temperature set points on
rheometer congurations R/S CPS+ P1 and P2 with Peltier temperature control.
After actuating the main control switch of the rheometer followed by a few seconds required
initial self-test, the following display screen is reached automatically: